- Automated Control.
- Display of full adsorption and desorption isotherms.
- Graph overlays.
- BJH pore size distribution.
- DFT pore size analysis method.
- αs plot (Alpha-s Plot).
- f-ratio plot.
- Freundlich and Temkin isotherms.
- Langmuir surface area.
- Horvath–Kawazoe method.
- Dubinin–Radushkevich method.
- Dubinin–Astakhov method.
- Micropore size distribution (Horvath–Kawazoe method).
- de Boer t‑plot method (for measurement of micropore volume in cc/g and micropore area in m²/g).
- Dead‑end and through‑pore analysis capability.
ChemMaster and BET Sorptometer
ChemMaster is designed as a versatile tool to investigate and extract information about surface chemistry and surface structure, which are important for the design, production, and application of catalytic materials. PMI’s ChemMaster measures the quantity of adsorbed or desorbed molecules, allowing determination of these characteristics. All measurements are performed quickly with high repeatability.
Additionally, a BET Sorptometer is provided to extend surface area measurement capability fora wide variety of materials.
PMI’s BET Sorptometer is a fully automated volumetric gas sorption analyzer used to accurately measure adsorption and desorption isotherms for the characterization of surface area, pore size distribution, pore volume, and pore structure of microporous and mesoporous materials, as well as adsorption kinetics.
PMI’s BET Sorptometer uses the same sample chamber for both micropore and mesopore analysis The same sample chamber is used for outgassing and testing.
Specifications:
| Pore Size Range | 0.35 to 500 nm or higher |
| Surface Area Range (in m²/g) | 0.0005 and above for all sample stations |
| Micropore Volume | Detectable within 0.0001 cc/g |
| Pressure Transducer | 1 sample chamber, 1000 Torr |
| Ultimate Vacuum | Up to 5 × 10⁻10 mbar |
| Resolution | 1 part in 60,000 |
| Accuracy | ± 0.15% of full scale |
| Analysis Gases | N2, O2, Ar, Kr, CO2, CO, H2, CH4, or other non‑corrosive gases |
| Adsorption Temperature | −195.6 °C (Nitrogen) |
| Regeneration System (Pretreatment system) | Temperature Range: Ambient to 400 °C |
| Power Requirements | 110 / 220 VAC, 50/60 Hz |
| In situ outgassing | No need for additional outgassing stations |